图1。ACSS sun sensor device ........................................................................................................................... 5 Fig 2.ACSS schematic ........................................................................................................................................ 5 Fig 3.Labeling ..................................................................................................................................................... 8 Fig 4.Angles reference ....................................................................................................................................... 8 Fig 5.Mechanical interface .................................................................................................................................. 9 Fig 6.Electrical interface ................................................................................................................................... 11 Fig 7.Signal acquisition recommended............................................................................................................. 11 Fig 8.Connector pin numbering ........................................................................................................................ 12 Fig 9.Spectral Responsivity .............................................................................................................................. 13 Fig 10.Sensor response of nominal and redundant units of ACSS .................................................................. 14 Tables
Appliance-Mode Security Platform for FTD or ASA Application • Fixed configurations: 4215, 4225, 4245 • Lightweight virtual Supervisor module w/ Multi-Instance and Clustering • Integrated Datapath FPGA w/Flow Offload and Crypto Engine • Rear dual redundant power supplies and triple fan trays
OperaƟng System Ubuntu server 20.04 LTS Processor (2) Intel Xeon Gold 5218 2.3G, 16C/32T, 10.4GT/s, 22M Cache, Turbo, HT (125W) DDR4-2666 RAID Controller PERC H740P RAID Controller, 8GB NV Cache, Mini card Memory 16GB RDIMM, 3200MT/s, Dual Rank Storage Chassis with up to 12x3.5" HDDs on BP, No Mid-Bay and 4x2.5" HDDs Flexbay, 1 or 2CPU Config Network Broadcom 5720 Quad Port 1GbE BASE-T, rNDC Power Supply Dual, Hot-plug, Redundant Power Supply (1+1), 1100W Power ConsumpƟon Periphials DVD-RW, Mouse,键盘外形架安装(2U)保修3/3/3(材料/劳动/现场)迷你保修美国硬件零件号soōware零件号
Cube Orange Autopilot三重冗余IMU的内部晴雨表双冗余电源双重供应二可以外围接口5通用串行接口端口端口端口3 GNSS接收器RTK RTK支持(Centimeter Level Supperication,tit Base Station具有基本站点)的整合指南针,ASPELEREREMERMONEL和GYROSPOPE。
将两 (2) 个 SPC810e 控制器模块安装到垂直 DIN 导轨上。将 SPC810e 控制器模块连接到冗余 HN800 I/O 总线。将 SPC810e 控制器模块连接到冗余 CW800 对等总线。为 PN800 控制网络提供四 (4) 个用于 100/1000 MB 以太网的 RJ45 连接器。
我们的 PGC 3000 是目前市场上最紧凑的专业冗余 GPS 时钟。它仅在一个高度单元中结合了功能齐全、冗余的高质量参考时钟。PGC 3000 涵盖了需要高精度参考信号以及精确时间戳的广泛应用。该设备非常适合数字视频和无线电广播应用。
A 侧:一组硬件组件的名称,可组成特定功能或功能集。它与另一组称为 B 侧的硬件完全冗余。当 A 侧正在使用时,它被视为主要环境的一部分,而 B 侧是次要(或冗余)环境的一部分。对于地面系统,当 A 侧为次要环境时,它可用于硬件和软件升级的安装测试和检查 (ITCO)。每一侧可能都有内部冗余组件。从 A 侧切换到 B 侧或从 B 侧切换到 A 侧可能是出于性能或故障原因。尽管 A 侧可能作为主要侧运行且没有故障,但当操作接受在 B 侧加载和检查的升级转换时,它可能被切换到次要侧。A 侧始终是 A 侧;名称不会改变。
可以通过安装由控制(主)和备用CPU组成的双控制系统来实现多级冗余系统。与冗余扩展基本单元和CC-Link IE场地网络的冗余扩展基本单元和网络电缆的双重扩展电缆拓扑结合在一起,可以将单点故障的风险最小化。在线更换电缆和模块(热扫)是可能的,而在发生错误时会连续操作系统,从而迅速进行故障排除。
• 所有桌面模块均支持热插拔。如果模块发生故障,可在运行期间断开 CAT 5 电缆并连接替换模块。大约 6 到 8 秒后,新模块将启动,工作可以继续,设置与事件发生前完全相同。• 桌面和 SCore 具有可选的冗余电源,这些电源由控制软件监控 • 所有 D21m I/O 模块均支持热插拔,可在运行期间根据需要进行更换 • DSP 卡支持热插拔 • 控制器卡支持热插拔;故障不会中断音频信号 • 错误消息显示在 GUI 上并记录在日志文件中,可以从网络中的任何位置对其进行监控和分析,从而立即采取行动 • 错误消息可能会生成外部警报信号、激活寻呼机或在移动电话上生成短信 • 网络交换机可选配冗余版本,带有冗余电源