AEO Annual Energy Outlook AK/HI Alaska and Hawaii CAES Compressed-air energy storage CAISO California Independent System Operator CPUC California Public Utility Commission CSP Concentrated solar power DOE U.S. Department of Energy EIA U.S. Energy Information Administration ERCOT Electric Reliability Council of Texas FERC Federal Energy Regulatory Commission GW Gigawatt IOU Investor-owned utilities ITC Investment Tax Credit IPP Independent power producer IRP Integrated resource plan ISO Independent System Operator ISO-NE Independent System Operator of New England kW Kilowatt kWh Kilowatthour LADWP Los Angeles Department of Water and Power MISO Midcontinent Independent System Operator MW Megawatt MWh Megawatthour NEMS National Energy Modeling System NYISO New York Independent System Operator PGE Pacific Gas and Electric PJM PJM Interconnection PPA Power purchase agreement RTO Regional Transmission Organization SCE Southern California Edison SDGE圣地亚哥天然气和电力SGIP自生激励计划Smud Sacramento Municipal Utility District SPP西南电力池
1932年法案大都会水区法案,1932年6月18日,AB组装法案ABARIZONA ELIZONA ELIGHT POWER POWER COMERATIC AI人工智能A.K.A.also known as BESS Battery Energy Storage System CAISO California Independent System Operator CEQA California Environmental Quality Act CEC California Energy Commission CO 2 -e carbon dioxide equivalent CPUC California Public Utilities Commission CRA Colorado River Aqueduct EF emission factor EMRS Energy Management and Reliability Study EO Executive Order ESP Energy Sustainability Plan GHG Greenhouse Gas GRP General Reporting Protocol ICS Intentionally Created Surplus kWh kilowatt-hour LADWP Los Angeles Department of Water and Power Metropolitan The Metropolitan Water District of Southern California MW megawatt MWh megawatt-hour NPV Net Present Value PPA Power Purchase Agreement REC renewable energy credits RPS renewable portfolio standard RPU Riverside Public Utilities SB Senate Bill SCADA supervisory control and data acquisition SCE Southern California Edison SGIP Self-Generation Incentive Program SWP州水项目TOU使用时间WAPA WAPA西部地区电力管理WTP水处理厂
处理科罗拉多州公用事业委员会(CPUC)4 CCR 723-3规则3850 - 3859设置了互连应用程序,审查,测试和批准的过程和时间表,请参见第13节链接。本手册,以及用于电动安装和使用的Xcel Energy标准,以满足此要求。公司关税P1-P6提供了少量的电力生产和热电联产政策。规则3850 - 3859(“委员会互连规则”)适用于所有电气资源,无论能源源和存储如何。这些来源是分布的能源(DER),通常在本手册中称为分布式生成(DG)。本手册主要解决互连的技术要求,但确实提供了一些有关互连过程的讨论,指导和其他信息。CPUC规则3850-3859仍然是最终权限。各方可以相互同意偏离,时间延长等。来自规则和互连手册中所述的内容。规则规定了三个级别的审查复杂性。第14节包含过程流程图,以帮助用户了解委员会互连规则中指定的三个审核级别的总体应用,审查,测试和批准过程。除非另有明确说明,否则本文档中的要求适用于互连客户生成的连续并行操作。本手册代表公司要求,关税和CPUC规则截至封面日期。在申请时将管理。分布式发电行业以及相关的规则和关税的变化速度比历史上的变化更快。所有各方都在学习如何整合较高的DG穿透性方面的学习曲线。虽然将对手册进行定期更新,但更新和这些关税,规则等之间将发生一些变化。三个审查级别是:1级(25 kW逆变器流程) - 对于基于逆变器的认证生成设施,在某些条件下,在径向或网络系统上,功率为25千瓦(KW)或更少。2级(快速轨道),有或没有补充审查 - 用于使用经过认证的互连设备生成设施,该设备通过某些指定屏幕,功率额定值为5.0兆瓦(MW)或更少。有关其他详细信息,请参考规则3855。级别3(完整的互连研究) - 用于生成具有10兆瓦或更低功率额定功率的设施,并且不具备简化或快速轨道流程的资格。CPUC 3900规则涵盖了10兆瓦以上的安装。CPUC 3900规则源自《原始公共公用事业监管法案》(PURPA)互连规则。3900规则对于时间表的结构和特定的审核过程步骤不像3850 - 3859规则那样结构。10 kW-10兆瓦申请表是申请过程的起点。完整过程类似于FERC SGIP(联邦能源监管委员会小型发电机互连过程)。FERC SGIP是对较大一代学院的合适替代过程。公司和客户在项目的申请阶段中应相互同意。可再生能源标准(RES)规则解决费率,回扣等。对于根据RES规则符合条件的DG设施。规则3900先前在3667中引用了0-10 MW